ISOLAIR

ISOLAIR

Permeable sarking board

PAVATEX sarking boards can be exposed to the weather for three months, and are “waterproof” according to the European standard EN 14964 for sarking boards. ISOLAIR sarking boards are simultane- ously also insulation boards, and can therefore be included in the cal- culation of the heat transfer. When used as sarking boards, please observe the country-specific application codes according to the regu- lations and standards in the technical documentation. ISOLAIR sark- ing board can be used as a vapour permeable, water repellent layer in external walls in timber constructions with clad walls.

Delivery form

Thickn. (mm) Weight [kg/sqm] Format (cm) Board dim. (cm) Number of boards per pallet [sqm] per pallet [kg] Edge profile
18* 4.32 250 x 77 248 x 75 54 103.95 464 Tongue and groove
22 5.27 250 x 77 248 x 75 44 84.70 462 Tongue and groove
35 7.00 250 x 77 248 x 75 30 57.75 419 Tongue and groove
52 10.40 250 x 77 248 x 75 20 38.50 415 Tongue and groove
60 12.00 250 x 77 248 x 75 17 32.73 408 Tongue and groove

* In the roof area: do not lay directly on the rafters, only use with over-rafter insulation.

Technical data ISOLAIR 18, 22 mm

Bulk density ρ [kg/m3] 240
Thermal conductivity (EN 13171) λD [W/mK] 0.047
Specific heat capacity c [J/(kgK)] 2100
Vapour diffusion resistance coefficient µ 5
Fire behaviour (EN 13501-1) Class E
Compressive stress at 10% compressive deformation [kPa] 180
Tensile strength perpendicular to plane of board [kPa] 30
Waste code according to the European Waste Catalogue (EWC) 030105; 170604
Identification code WF-EN13171-T5-DS(70.-)2-CS(10\Y)160-TR30-WS1,0-MU5-AF100
Sarking board (EN 14964) SB.E

Technical data ISOLAIR 35, 52 & 60 mm

Bulk density ρ [kg/m3] 200
Thermal conductivity (EN 13171) λD [W/mK] 0.044
Specific heat capacity c [J/(kgK)] 2100
Vapour diffusion resistance coefficient µ 3
Fire behaviour (EN 13501-1) Class E
Compressive stress at 10% compressive deformation [kPa] 250
Tensile strength perpendicular to plane of board [kPa] 30
Waste code according to the European Waste Catalogue (EWC) 030105; 170604
Identification code WF-EN13171-T5-DS(70.-)2-CS(10\Y)250-TR30-WS1,0-MU3-AF100
Sarking board (EN 14964) SB.E
Switzerland
Declared thermal conductivity SIA λD [W/mK] 0.047
Fire index according to VKF (BKZ) 4,3